User Tools

Site Tools


connect-or-not-zurich

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
connect-or-not-zurich [2015/04/29 12:46]
zoza [Connect or Not: Buhne A, Zurich, November 2013]
connect-or-not-zurich [2015/04/29 13:09]
zoza [software]
Line 2: Line 2:
  
 {{::​image1772.png?​nolink&​590|}} {{::​image1772.png?​nolink&​590|}}
 +
 +===== interaction scheme =====
 +
 +{{::​milicone-interaction-scheme.png?​400}}
  
 Android application > OSC data stream > Puredata patch  Android application > OSC data stream > Puredata patch 
Line 28: Line 32:
             |                        receive-osc.py > log/​log(+UNIXtimestamp).txt <:49999             |                        receive-osc.py > log/​log(+UNIXtimestamp).txt <:49999
             |_______________________ milicone-direct-backup.py > log(+UNIXtimestamp).txt             |_______________________ milicone-direct-backup.py > log(+UNIXtimestamp).txt
-===== interaction scheme ===== 
- 
-{{::​milicone-interaction-scheme.png?​400}} 
  
 ===== technical details ===== ===== technical details =====
 +
 +RGB LED theatre lights + DMX shield + Arduino + Connect or Not Android app + laptop
  
 ==== hardware ==== ==== hardware ====
  
-  * DMX RGB spot lights +  * RGB LED light spots: //Teclumen Fusion color 18 FC RGBW//; ({{http://​www.ecm-sa.ch/​files/​stage_color_18_fc_manuale.pdf|datasheet}}) DmxSetup: [1RGB, 8 channel]; ([[teclumen-test-pd]]) ​/OR/ //Wybron Cygnus VN100 model 7500// ({{http://​www.wybron.com/​stage-lighting-service-and-repair/​documentation/​user-manuals/​Cygnus_ColorWash_Manual_v1.8.pdf|datasheet}}) DmxSetup: addr 0001 /// res 8bit /// fdr ON /// HSP OFF /// ([[wybron-test-pd]]) 
-  - Teclumen Fusion color 18 FC RGBW; ({{http://​www.ecm-sa.ch/​files/​stage_color_18_fc_manuale.pdf|datasheet}}) DmxSetup: [1RGB, 8 channel]; ([[teclumen-test-pd]]) +  * Arduino ​Uno 
-  - Wybron Cygnus VN100 model 7500 ({{http://​www.wybron.com/​stage-lighting-service-and-repair/​documentation/​user-manuals/​Cygnus_ColorWash_Manual_v1.8.pdf|datasheet}}) DmxSetup: addr 0001 /// res 8bit /// fdr ON /// HSP OFF /// ([[wybron-test-pd]]) +  * DMX shield by [[https://​www.tindie.com/​products/​Conceptinetics/​25kv-isolated-dmx-512-shield-for-arduino-rdm-capable-r2|Conceptinetics]] 
-  * Arduino ​DMX shield by {{https://​www.tindie.com/​products/​Conceptinetics/​25kv-isolated-dmx-512-shield-for-arduino-rdm-capable-r2|Conceptinetics}} +  * laptop ​(Debian Wheezy) with built in wireless adapter Intel® Centrino® Advanced-N 6205 with Intel(R) Wireless WiFi driver for Linux, 3.11-2-amd64 (iwlwifi) 
-  * laptop ​running ​Debian Wheezy+  * smartphone (Samsung Galaxy S3, Android 4.0.4)
  
-  * connect or not: [[connect-or-not-setup|researching the setup]] 
 ==== software ==== ==== software ====
  
-  * Arduino [[DMX-simple|DMX Simple]] library ​(not the same DMX simple that comes by default!!! modified pin 2 to be always high) +  * Arduino [[DMX-simple|DMX Simple]] library, customized 
-  * [[arduino-pd|arduino.pd]] ​(place it in the working folder) +  * [[arduino-pd|arduino.pd]]  
-  * puredata ​test patches +  * puredata ​patch with OSC server and lights controls [[wybron-pd|puredata ​patch using Wybron]] OR  ​[[teclumen-pd|puredata ​patch using Teclumen]] lights ​ 
-  ​- puredata [[teclumen-test-pd|Teclumen test patch]] +  ​* to test the light spots only, use puredata ​test patch for [[teclumen-test-pd|Teclumen ​test patch]] ​OR [[wybron-test-pd|Wybron test patch]] 
-  ​puredata [[wybron-test-pd|Wybron ​test patch]] + 
-  * puredata patch (Wybron version is the newest) + 
-  - Connect or not > OSC > DMX [[wybron-pd|puredata ​patch using Wybron]] lights ​ +connect ​or not[[connect-or-not-setup|researching the setup]]
-  - Connect ​or not > OSC > DMX [[teclumen-pd|puredata patch using Teclumen]] lights+
  
 +===== HOWTO =====
connect-or-not-zurich.txt · Last modified: 2015/04/29 14:01 by zoza